100-240VAC Input 24V DC 42A Power Supply 1000W SMPS

DC 24V 42A power supply 1000W

Description:
24V switching power supply 1000W is suitable for use in LED stage lighting, networking, test and measurement, IT applications, general electronics, automation, motor, based machinery and etc.

Features:
1, High efficiency 1200W switching power supply;
2, Built-in EMI filter and PFC function, low noise, high reliability;
3, 24V power supply with wide range of AC input voltage ;
4, 1200W power supply with overload,short circuit,over-voltage and over temperature protection;

Parameter
Item NOK19H-UP1200S12FK19H-UP1200S24FK19H-UP1200S28FK19H-UP1200S36FK19H-UP1200S48F
OutputOutput Voltage+12VDC+24VDC+28VDC+36VDC+48VDC
Rated Current80A50A42A33A25A
Rated Power960W1200W1200W1200W1200W
Ripple & Noise240mVp-p250mVp-p280mVp-p360mVp-p400mVp-p
Output ADJ.Range11.4-12.6V22.8-25.2V26.6-29.4V34.2-37.8V45.6-50.4V
Output Accuracy±1%
Line Regulation±0.5%
Load Regulation±1%
Set up,Rise,Keep up time500ms,30ms,20ms
InputInput Voltage Range100-240V AC
Input Current6A/230Vac,12A/115Vac
Input Frequency50-60Hz
Efficiency @230Vac90%92%92%93%93%
Power FactorPF>0.98/115V or PF>0.95/230V
Inrush CurrentCold start 40A/230Vac
Leakage Current<0.5mA@240V
ProtectionOver Load105~150% Hiccup,automatic recovery
Short Circuit
Hiccup,automatic recovery
Output Over Voltage
120% Shut downLocked protection,  Return to normal after restart
Over Temp.,
105℃ it will be protection, then automatic recovery
FunctionsFan Supply
12V@0.3A for driving a fan, tolerance±15%, Built-in fan forced air cooling
EnvironmentWorking Temp., Humidity
-20~60℃10~90% RHNo condensation
Storage Temp., Humidity
-20~85℃10~95% RH
Temp,. Drift
±0.03%/℃ (0~50℃)
Vibration
10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES
Satety & EMCSafety StandardsGB4943 
Withstand Voltage
I/P-O/P:3KV; I/P-FG1.8KVO/P-FG:0.6KV AC 1min
Insulation Resistance
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms
EMC StandardsEN55032 CLASS A EN61000-3-2
OthersMTBF>50K hrs
Dimension180*82*48mm(L*W*H)
Weight1.5KG
Notes
1. All parameters 230VAC input, rated load, ambient temperature 25 ℃, measured under conditions of 70% humidity;
2. Accuracy: includes set up tolerance, line regulation, load regulation and so on;
3. Ripple Test: 30cm long strands connect the power supply and the load on the load side and 0.1u and 47u capacitor to 20MHz oscilloscope measured at the load end;
4. Line regulation: at rated load conditions, the input voltage changes from low to high measured;
5. Load regulation: the measured output load from 0 to 100% load change measured;

Product picture: